Air duct calculator - The equal friction method for sizing air ducts is often preferred because it is quite easy to use. The method can be summarized to. Compute the necessary air volume flow (m 3 /s, cfm) in every room and branch of the system; Use 1) to compute the total air volume (m 3 /s, cfm) in the main system; Determine the maximum acceptable airflow velocity in the …

 
Duct calculator. Air and liquid duct; Calculate duct flow resistance, environmental heat exchange, and adiabatic; Note: outer coefficient of heat transfer usually is 3~10, >10 when winds. Download & Buy. For windows, without network and browser limits.. Smf to vegas

Air Duct Calculator/Ductulator with Sleeve. 3.9 out of 5 stars 14. $14.70 $ 14. 70. FREE delivery Jun 30 - Jul 6 . Flexible Duct Friction Loss Calculator/Flex Duct ... Ordinary heating, ventilating, and air conditioning duct systems read air pressures at 0.4 psi or less, often much less. 1 psi equals 27.7 inches of water gauge; a common duct pressure of 0.25 inches water column is equal to (0.25 divided by 27.7 in-wc/psi) = 0.009 psi. Duct Pressure: Duct system is pressurized by three pressures: • Free HVAC Duct Sizing - in SI/Metric or US/Imperial units. Welcome to CalcuDUCT - the quick and easy way to size ducts for any HVAC application. Now, to properly calculate the return grille size, we have to make these two assumptions: Face velocity is 500 FPM (feet per minute). This is the speed at which the return grille sucks the air from your house into your ducts. Free grille area is 70%. As we know, the grille is always bigger than the duct through which the airflow flows.This calculation Excel program makes it possible to carry out the calculation of the pressure losses on the duct works and air distribution systems. Download Duct Friction Loss Excel Calculator: Fan static head is calculated according to the duct friction loss. the more the value of friction loss is the more the static head of …The Ductulator - Duct Sizing Calculator is a hand held rotating calculator used for sizing supply and return duct systems using the equal friction design method. This accurate, easy-to-use duct size calculator includes scales for friction loss per unit length, air volume, air velocity, round duct diameter and rectangular duct diameters.These calculations are divided in four areas: 1. Diameter converter, which allows converting circular to equivalent rectangular ducts. 2. Calculator of different ventilation parameters, with which will be able to obtain the diameter, the air speed, the airflow and the dynamic pressure of your installation. 3.TO CALCULATE DUCT SIZE: Enter Air Quantity (Flow Rate) Enter either Friction Loss or Velocity. The software will automatically detect the calculation method; Click Calculate …The duct weight can be calculated using the following formula: DW = ( (2* (H+W)) L T)*D. Where the variables are: The duct density for aluminum is 0.1 lbs/in^3. To calculate duct weight, simply multiply the sum of the height and width by 2, multiply the result by the length and thickness, and then multiply the final product by the density.The chart below can be used to estimate velocities in air ducts. The default values are for air flow 400 cfm (680 m3 /h) , duct size 8 in (200 mm) and velocity 1150 fpm (5.8 m/s) . Download and print Air Ducts - Velocity …Apr 25, 2022 · At 350-400 CFM per 12,000 BTUs of heating capacity, there’s enough airflow to circulate heated air through supply ducts and pull cool air back to the furnace or air handler through the cold air returns. A 3-ton unit, or 36,000 BTUs, would need a blower capable of moving 3 x 350-400 CFM, so a total of 1,050 to 1,200 CFM. The Duct Area Calculator is a powerful tool designed to help individuals and professionals in the HVAC industry determine the cross-sectional area of rectangular and circular ducts. This essential calculation aids in optimizing airflow, ensuring efficient ventilation systems, and maintaining optimal indoor air quality.Air Ducts - Cross Sectional Areas; Example - Generated Noise in Duct by Air Flow. The cross section area of a 200 mm duct can be calculated as. A = π ((0.2 m) / 2) 2) = 0.0314 m 2 The noise generated in the duct with an air flow velocity 10 m/s can be calculated as. L N = 10 + 50 log (10 m/s) + 10 log (0.0314 m 2) = 45 db The noise generated in the same …Best prices guaranteed. We match other Aussie retailers*. Use our sizing calculator below to determine the minimum size required for your room or house. Remember for ducted systems only include the air conditioned spaces, exclude areas like … Duct Size Calculator. Ductulator is an engineering tool to calculate air duct dimensions based on given inputs including air-flow, duct material roughness and either air pressure static loss (friction method) or air velocity (velocity method). This online ductulator calculates the dimensions for both round and rectangular duct options (one ... The cross-sectional area of the duct is: Then the mass flow rate of air through the duct and the rate of heat loss become. therefore, or 5688 kJ/h. The cost of this heat loss to the home owner is. Conversion: 1 Therm = 105,480 kJ. Conclusion: The heat loss from the heating ducts in the basement is costing the home owner 4 cents per hour. Duct Size Calculator. Ductulator is an engineering tool to calculate air duct dimensions based on given inputs including air-flow, duct material roughness and either air pressure static loss (friction method) or air velocity (velocity method). This online ductulator calculates the dimensions for both round and rectangular duct options (one ... Aug 21, 2023 · Cleaning helps not only remove them, but may also remove blockages that can help make your system run more efficiently. Keep reading to learn more about the cost of duct cleaning services. 2024 Duct Cleaning Costs. Calculate local project costs by entering your zip code. Typical Price Range. $ 450 - $ 1,000. Example - Calculate Reynolds Number. A Newtonian fluid with a dynamic or absolute viscosity of 0.38 Ns/m 2 and a specific gravity of 0.91 flows through a 25 mm diameter pipe with a velocity of 2.6 m/s .. Density can be calculated from the specific gravity of the fluid and the density of the specific gravity reference water 1000 kg/m 3 - as. ρ = 0.91 (1000 …Quickly find the duct diameter best suited to your needs, based on the desired air flow rate and the air velocity in the network. The tool will give you the diameter best suited to your …ρ = 999.7 kg/m³. Find the dynamic viscosity: µ = 0.001308 kg/ (m · s) Compute the product of the density of water, the velocity of the flow, and L: ρ × u × L = 249.925 (m · s)/kg. Divide the result by the dynamic viscosity to find the Reynolds number: ReD = 249.925/0.001308 = 191,074 The flow is likely turbulent.Section 5 - Air Distribution System Design This section provides an executive overview of duct system design procedures, additionally covering the use of a branch take off fitting at the end of a supply air trunk duct. Section 6 - Duct Sizing Calculations This section covers the duct system design procedures in detail.Quickly find the duct diameter best suited to your needs, based on the desired air flow rate and the air velocity in the network. The tool will give you the diameter best suited to your …Knowledge is power, so although we can't always correct the problems we see with duct work, I'm hoping that with some knowledge we can make some little chang...Calculation Method. Static Pressure Loss [inW/100ft] Air Flow [CFM] 3000 FPM. Round Duct Air Velocity. Infinity FPM. Rectangular Duct Air Velocity. 0.00049 Absolute Roughness [Foot] 14.42.Air Duct Elbow Loss. Calculation of pressure loss in elbows on ventilation ducts. Fill in the form below. Wid. (W)/Heig. (H) Calculation of local losses in elbows in ventilation ducts. Air Duct Calculator. Double-sided. Side 1 = standard ducloator with calculations for both round and rectangular duct. Side 2 = Continental vs competitive cross reference for some common GRDs and a Grille sizing chart. Qty 25/package. V = 0.408 Q/D 2. Components. = Air velocity inside the duct (feet/s) = Air flow rate inside the duct (GPM) = Air flow rate inside the duct (inches) Metric Equation. Determine the following formula, which can be used to calculate the air duct velocity: V …To adequately calculate the speed of air in ducts, we have to primarily calculate the cross-section of the duct. Shape-wise, ducts can be: Round. The area of round flex ducts is calculated as π*R 2 where R is the radius of the duct. Example: 10-inch round duct has a radius of 5 inches.Apr 6, 2024 · The Duct Size Calculator is a quick reference tool for approximating duct size and equivalent sizes of sheet-metal duct and flexible duct. A new duct-sizing calculator from ASHRAE and the Air Distribution Institute (ADI) allows HVAC air-distribution-system designers to size ducts more accurately, especially flex ducts under varying amounts of ... Duct work attenuation. Calculate the attenuation in unlined and lined ducts. Note that the table and diagrams list the attenuation in dB/m. 13. ... The speed and attenuation of sound in moist air varies with sound frequency and air humidity. Sound Attenuation - …September 17, 2023 by GEGCalculators. Converting round to rectangular duct sizes depends on specific design factors. As a rough approximation, a round duct with a diameter of 6 inches might correspond to a rectangular duct of 8×4 inches, but these conversions vary based on project requirements. Precise calculations should be made using HVAC ...An Air duct pressure drop calculation is essential for designing and operating HVAC (Heating, Ventilation, and Air Conditioning) systems. Understanding how to calculate pressure drops in air ducts allows mechanical engineers to design more efficient and effective systems, ensuring optimal airflow and comfort in residential and commercial …The pressure losses in ducts are caused by friction between the air and the duct surfaces, as well as by fittings and bends in the duct system. How do you calculate CFM from pressure drop? CFM (Cubic Feet per Minute) can be calculated from pressure drop using the fan laws, which relate CFM, pressure, and fan performance.1. Diameter converter, which converts circular diameters to equivalent rectangular ducts. 2. Ventilation parameter calculator allows the diameter, air speed, airflow and dynamic pressure of your installation to be calculated. 3. Pressure drop calculation tool for installations with straight sections and duct system elements. 4.The Duct Sizing Calculator is a hand held sliding calculator used for sizing supply and return duct systems using the equal friction, or velocity reduction design method. Front of calculator includes scales for friction, velocity, round duct size, weight per linear foot of round duct, surface area in square feet per lineal foot of round duct ...Ductulator - Duct Diameter Calculator. Enter the required volume & velocity to see the necessary duct diameter. Required Air Volume. m³/sec m³/hr. Required Air Velocity. m/sec. Duct Diameter. mm. Health and Safety Executive recommended minimum duct …Instructions. (Input information may generally be be obtained from design documents or field measurements) Line 1. Enter the temperature of the air entering the duct. Line 2. Enter the ambient temperature (the average temperature of the air surrounding the duct) Line 3. Enter the flow rate of the air carried by the duct in cubic … FPM. Max. Static Loss/100ft: InWg. Free online ductulator for sizing of HVAC ducts. QUICK-GUIDE. Select the duct material from the drop-down list (most duct sizing tools are typically based on galvanised steel ducting by default) Enter the air flowrate in litres/second (can change to cubic metres/second by …Duct Size Chart. Do your own calculations and compare them to our chart – or use the chart for quick, accurate calculations for duct size based on CFM needed for a room. One size is given for round ducts, its diameter. You have two or three options for rectangular ducts that give you the same or nearly the same square footage per duct.Apr 25, 2022 · At 350-400 CFM per 12,000 BTUs of heating capacity, there’s enough airflow to circulate heated air through supply ducts and pull cool air back to the furnace or air handler through the cold air returns. A 3-ton unit, or 36,000 BTUs, would need a blower capable of moving 3 x 350-400 CFM, so a total of 1,050 to 1,200 CFM. The duct weight can be calculated using the following formula: DW = ( (2* (H+W)) L T)*D. Where the variables are: The duct density for aluminum is 0.1 lbs/in^3. To calculate duct weight, simply multiply the sum of the height and width by 2, multiply the result by the length and thickness, and then multiply the final product by the density. All Duct Calculator. An inclusive air duct calculator for diameter, velocity, CFM, and pressure drop of various types of duct. It will also determine round duct equivalents for rectangle, flat oval, and elliptical (flattened round) duct. Duct roughness and air properties are adjustable and includes a metric option. Open Calculator. To calculate the kinematic viscosity of air at pressure 1 bar (105 Pa) and 50 °C, enter a few details into the kinematic viscosity of air calculator: Convert the temperature in Celsius to kelvin: T = 273.15 K + 50 = 323.15 K. Calculate the density of the air from the ideal gas law: ρ = P/ (RT) = 105 Pa/ (287.05 J/kg·K × 323.15 K) = 1.078 kg/m3.The Duct Sizing Calculator is a hand held sliding calculator used for sizing supply and return duct systems using the equal friction, or velocity reduction design method. Front of calculator includes scales for friction, velocity, round duct size, weight per linear foot of round duct, surface area in square feet per lineal foot of round duct ...The equal friction method for sizing air ducts is often preferred because it is quite easy to use. The method can be summarized to. Compute the necessary air volume flow (m 3 /s, cfm) in every room and branch of the system; Use 1) to compute the total air volume (m 3 /s, cfm) in the main system; Determine the maximum acceptable airflow velocity in the …Here’s some insight from this chart: To produce 1 CFM, we would need 11.46 FPM, 5.09 FPM, 2.86 FPM, and 1.83 FPM air velocity in 4-inch, 6-inch, 8-inch, and 10-inch round duct, respectively.We can clearly see that we need lower FPM per CFM the larger the duct we use. For 100 CFM, we need between 183.35 FPM and 1145.92 FPM, if we use 4-10 inch …The circuit of the cold air ducts is calculated for 100% of the necessary flow. On the other hand, for the hot air ducts, one admits 50% to 75% of the cold air flow according to thermal loads. The variation between the temperature of the buildings in summer and the air in the cold air duct is 50 to 55.5 °F (10 to 13°C).Now, we can use the previous equation to calculate the makeup air rate for kitchens and dryers under these conditions. (1) 400 – 190 = 210 CFM of makeup air (2) 200 – 190 = 10 CFM of makeup air. Makeup Air Duct Size. Below is a table of the average air inflow rates through different size ducts at different air pressures:Example 2.5 ton Duct System Diagram. Sizing for a 2.5 Ton unit, we start with a 16" supply at 875 CFM -1125 CFM. We then take a 7" and 5" run (-200 CFM) off of this section bringing the remaining total to 675 CFM - 925 CFM. A drop from 16" to 14" in now required to keep pressure and velocity up.JP Lamborn Co. ( JPL ) began producing flexible air ducts in 1961. Today the company operates four state-of-the-art manufacturing facilities and is the largest family-owned flexible air duct manufacturer in North America. JPL’s core values of manufacturing high-quality products, providing excellent service, innovation, and strong business ...Air Ducts - Cross Sectional Areas; Example - Generated Noise in Duct by Air Flow. The cross section area of a 200 mm duct can be calculated as. A = π ((0.2 m) / 2) 2) = 0.0314 m 2 The noise generated in the duct with an air flow velocity 10 m/s can be calculated as. L N = 10 + 50 log (10 m/s) + 10 log (0.0314 m 2) = 45 db The noise generated in the same …Ducting Calculators and Air Volume Converter. Nordfab can offer technical assistance with determining whether our ducting is best for your application and with designing duct installations. Please contact us with your requirements. Input CFM Input Velocity (FPM) Ideal Round Duct Diameter Duct Friction in Straight Duct. Calculate.Air Duct Calculators (Ductulator) 2/5. Watch on. This handy little device allows you to size your new air duct, and better understand what to expect from existing duct work. A Ductulator helps you properly size your ducts, estimate air loss, find the round or rectangular duct equivalent, and determine velocity. It can prevent some costly errors ...Adjustable Absolute Duct Roughness. If selected, Flexible roughness is 0.003 ft when. straight and fully stretched tight at 0% compression. (adjusted at other compressions), otherwise the. original method of constant 0.01 ft roughness is used. Use ASH RAE 2013 Flex Compression.Air duct cleaning redefines home health. Eliminating dirt, dust and microbial growth from your ductwork can improve indoor air quality while maintaining a cleaner home and increasing HVAC efficiency. Clean ducts mean less dirt in your home and air because ductwork is often the source and pathway for dust and biological contaminants.The cross-sectional area of the duct is: Then the mass flow rate of air through the duct and the rate of heat loss become. therefore, or 5688 kJ/h. The cost of this heat loss to the home owner is. Conversion: 1 Therm = 105,480 kJ. Conclusion: The heat loss from the heating ducts in the basement is costing the home owner 4 cents per hour.PRODUCT DETAILS. AIR DUCT SLIDE RULE CALCULATOR. Size: 4"x9.25". Material: Heavyweight coated calculator board. Production: Each order is custom manufactured with your company information and in your choice of colors. AIR DUCT WIZARD DUCTULATORS. Size: 8.5"x11" card with a 7.25" wheel. Materials: Heavyweight coated … Purchase ADI Ductulator. The ADI - Air Distribution Institute, was formed in 1947 to promote the use of fabricated steel duct pipe and fittings for air distribution products. Today the alliance of ADI member companies produce steel duct pipe and fittings designed to efficiently deliver conditioned air in your home and office. AllDuctCalc™ - HVAC Air Duct Calculator v2 Updated 10/26/15: Provide inputs in the blue boxes, other inputs optional. All Duct Calculator. An inclusive air duct calculator for diameter, velocity, CFM, and pressure drop of various types of duct. It will also determine round duct equivalents for rectangle, flat oval, and elliptical (flattened round) duct. Duct roughness and air properties are adjustable and includes a metric option. Open Calculator. Now, we can use the previous equation to calculate the makeup air rate for kitchens and dryers under these conditions. (1) 400 – 190 = 210 CFM of makeup air (2) 200 – 190 = 10 CFM of makeup air. Makeup Air Duct Size. Below is a table of the average air inflow rates through different size ducts at different air pressures:About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ...Using the chart, you’ll see that for a 12” round flex duct, maximum CFM is 480 CFM or 500 CFM depending on the friction rate. Duct size for 115 CFM. Find the CFM closest to 115 in the table above. It will be found in different columns depending on the friction rate. If there isn’t an exact match, go up to the duct size.The Duct Pressure Loss Calculator is an essential tool used to estimate the pressure drop or loss that occurs within a duct system due to various factors such as friction, length, diameter, velocity of airflow, and gravity. Its primary function is to calculate the pressure loss (ΔP) occurring in the duct, offering insights into the system’s efficiency.Online Head Loss Calculator. The calculator below, which is based on eq. (2) , can be used to calculate the head loss in a duct, pipe or tube.The default values used in the calculator are for air flow 20 o C , 1.2 kg/m 3 and 6 m/s .The default density of water commonly used as reference fluid is 1000 kg/m 3.The friction coefficient is calculated …A simple volume unit converter to convert air flow volumes from ... Calculate the equivalent size of spiral ducting when you have only been given the rectangular duct dimension (it works the other way also) Open the ES Calculator. System Pressure Calculator. The System Pressure Calculator helps you work out the resistance in pascals that ...Lindab Vent Tools app streamlines ventilation system calculations with practical tools for HVAC professionals. This handy app offers a collection of practical calculation tools for the HVAC industry, including duct dimensioning, pressure drop, airflow, and offset calculation for Lindab's products. The app also includes a k-factor calculator for versatile use …The head loss calculator below is based on formula (1) : Air Volume Flow - q - (cfm) Equivalent duct diameter - d e - (inches) Duct Length - (feet) Equivalent Diameter - …Section 5 - Air Distribution System Design This section provides an executive overview of duct system design procedures, additionally covering the use of a branch take off fitting at the end of a supply air trunk duct. Section 6 - Duct Sizing Calculations This section covers the duct system design procedures in detail.Ordinary heating, ventilating, and air conditioning duct systems read air pressures at 0.4 psi or less, often much less. 1 psi equals 27.7 inches of water gauge; a common duct pressure of 0.25 inches water column is equal to (0.25 divided by 27.7 in-wc/psi) = 0.009 psi. Duct Pressure: Duct system is pressurized by three pressures: •Enter 6" into the Duct Height (Optional) field. The results table show a 10"x6" duct. This calculator can also be used to simply convert round to rectangular or vice versa. It is unnecessary to consider the duct material, length, or air volume since it is just a physical, geometric calculation. Assume we have an 18" round duct.These calculators estimate the temperature drop (or rise) of air flowing in a duct or fluid flowing in a pipe. An example is the use of insulation to minimize temperature change (either temperature drop or rise) of a process fluid from one location to another(e.g. a hot fluid flowing down a pipe). Temperature Drop Calculator for Air DuctsOnline Head Loss Calculator. The calculator below, which is based on eq. (2) , can be used to calculate the head loss in a duct, pipe or tube.The default values used in the calculator are for air flow 20 o C , 1.2 kg/m 3 and 6 m/s .The default density of water commonly used as reference fluid is 1000 kg/m 3.The friction coefficient is calculated …Pull the airflow vertically to hit the friction loss line at 0.1 in.wg. Then, pull the line diagonally to the right and find the suitable duct diameter. 14″ round duct is less than ideal because the friction loss will be greater than 0.1 …mdot = Q / (cp x Δt) Calculate air mass flow rate from cooling load. All Duct Calculator. An inclusive air duct calculator for diameter, velocity, CFM, and pressure drop of various types of duct. It will also determine round duct equivalents for rectangle, flat oval, and elliptical (flattened round) duct. Duct roughness and air properties are adjustable and includes a metric option. Open Calculator. A duct size calculator, commonly known as a ductulator, depends on factors like the size of the space you’re heating or cooling, air flow …

Apr 6, 2024 · The Duct Size Calculator is a quick reference tool for approximating duct size and equivalent sizes of sheet-metal duct and flexible duct. A new duct-sizing calculator from ASHRAE and the Air Distribution Institute (ADI) allows HVAC air-distribution-system designers to size ducts more accurately, especially flex ducts under varying amounts of ... . Sope 2 day

air duct calculator

Ductulator - Hand held rotating calculator used for sizing supply and return duct systems using the equal friction design method. Includes scales for friction loss per unit length, air volume, air velocity, round duct diameter, and rectangular duct diameters. One side uses English units, the other side uses Metric units. Air Duct Elbow Loss. Calculation of pressure loss in elbows on ventilation ducts. Fill in the form below. Wid. (W)/Heig. (H) Calculation of local losses in elbows in ventilation ducts.In April 2024 the cost to Install a Duct starts at $12.13 - $21.39 per linear foot. Use our Cost Calculator for cost estimate examples customized to the location, size and options of your project.. To estimate costs for your project: 1. Set Project Zip Code Enter the Zip Code for the location where labor is hired and materials purchased.. 2. Air Duct Calculator. Double-sided. Side 1 = standard ducloator with calculations for both round and rectangular duct. Side 2 = Continental vs competitive cross reference for some common GRDs and a Grille sizing chart. Qty 25/package. CFM (10×12 Duct, 500 FPM) = 500 FPM × 10 Inches × 12 Inches / 144 = 416.67 CFM. We can see that the 10×12 duct generates 416.67 CFM of airflow at 500 FPM air speed. Now, we did a huge amount of calculations for these rectangular ducts at 1 FPM, 500 FPM, and 2000 FPM, and gathered all the results in this feet per minute to cubic feet per ...Download HVAC Duct Quantities, Weight and Area Calculation Sheets. Air Duct quantity can be estimated in sq. meters or kilograms. These excel sheets will enable you to calculate or estimate the duct weight or the duct surface area.Example of big metal round and rectangular ducts (3,000+ CFM airflow). To figure out exactly how big ducts you need for central air conditioning systems, we have prepared complete CFM duct charts for all different kinds of ducts:. Duct sizing chart for flex ducts (round ducts with 5-20 inch diameter).; Duct sizing chart for metal ducts (round ducts …Get free shipping on qualified Ducting & Venting products or Buy Online Pick Up in Store today in the ... resistant, 4-ply aluminum foil laminate that encapsulates a high density, corrosion resistant wire helix. This forms an air tight and easy to use air duct. View Product. Explore More on homedepot.com. Doors & Windows. 1 Panel 36 x 79 ...2. Calculator of different ventilation parameters, with which will be able to obtain the diameter, the air speed, the airflow and the dynamic pressure of your installation. 3. Pressure drop calculation tool for installations with …The equal friction method for sizing air ducts is often preferred because it is quite easy to use. The method can be summarized to. Compute the necessary air volume flow (m 3 /s, cfm) in every room and branch of the system; Use 1) to compute the total air volume (m 3 /s, cfm) in the main system; Determine the maximum acceptable airflow velocity in the …Duct Size Chart. Do your own calculations and compare them to our chart – or use the chart for quick, accurate calculations for duct size based on CFM needed for a room. One size is given for round ducts, its diameter. You have two or three options for rectangular ducts that give you the same or nearly the same square footage per duct. A major friction loss diagram for air ducts - SI units. Air Ducts - Friction Loss Diagram A major friction loss diagram for air ducts - Imperial units ranging 10 - 100 000 cfm. Air Ducts - Velocity Diagram Air flow volume, duct size, velocity and dynamic pressure. Circular Ducts - Dimensions Standard size of circular ventilation air ducts. Duct ... HVAC Ductwork Sizing Calculator. On this page: How to size your HVAC ductwork? Understanding measurement units for ducts. Using Modernize's HVAC and … Duct-U-Lator. This app works as a Ductulator and Pressure Loss (friction) calculator which has the following functions. Converts Duct Shape or Size to Another. Determines Sizes for a Given Friction Rate. Determines Sizes for a Given Velocity. Determines Sizes for a Given Velocity and a Friction Loss Rate (simultaneous output) .

Popular Topics